Using the IDPF network interface

Bare metal instances available with machine series such as C3 and X4 use Infrastructure Data Path Function (IDPF), which is a standardized, multi-vendor PCIe network data plane function device. IDPF is a physical device. The IDPF driver is included in the kernel of Linux operating system (OS) images.

Before you begin

  • If you haven't already, set up authentication. Authentication verifies your identity for access to Google Cloud services and APIs. To run code or samples from a local development environment, you can authenticate to Compute Engine by selecting one of the following options:

    Select the tab for how you plan to use the samples on this page:

    gcloud

    1. Install the Google Cloud CLI. After installation, initialize the Google Cloud CLI by running the following command:

      gcloud init

      If you're using an external identity provider (IdP), you must first sign in to the gcloud CLI with your federated identity.

    2. Set a default region and zone.

    REST

    To use the REST API samples on this page in a local development environment, you use the credentials you provide to the gcloud CLI.

      Install the Google Cloud CLI.

      If you're using an external identity provider (IdP), you must first sign in to the gcloud CLI with your federated identity.

    For more information, see Authenticate for using REST in the Google Cloud authentication documentation.

Supported features with IDPF

Similar to gVNIC, the following features are supported with IDPF:

Limitations of IDPF network interfaces

When using IDPF network interfaces (vNICs), note the following limitations:

  • For most bare metal machine types, only a single vNIC is supported for the instance, meaning you can't create a bare metal instance with multiple IDPF network interfaces. The exceptions are as follows:
    • A5X and A4X Max bare metal: Up to 2 IDPF network interfaces, plus the MRDMA network interfaces for GPU networking
    • (Preview) C4D bare metal: Up to 10 IDPF network interfaces
    • Z4D bare metal: Up to 2 IDPF network interfaces
    • Z4M bare metal: Up to 2 IDPF network interfaces, and up to 2 IRDMA network interfaces
  • IDPF supports a default queue allocation of 16 receive and transmit queues (RX/TX) per NIC, with the following exceptions:
    • A5X and A4X Max bare metal: 64 queues per IDPF NIC by default
    • Z4D and Z4M bare metal: Up to 64 queues per IDPF NIC
  • If you use DPDK with a bare metal instance that supports only one vNIC, then DPDK replaces the IDPF as the driver for the physical NIC. The DPDK application must forward packets to the kernel, such as through a TAP interface.

Overview of using IDPF with bare metal instances

To create a bare metal instance that uses IDPF, complete the following steps:

  1. Choose a public OS image that supports IDPF, or create a custom OS image that is tagged to use IDPF.
  2. Create a bare metal instance using the public or custom OS image. During instance creation, configure the network interface to use IDPF.
  3. Verify that IDPF is enabled.

Operating system support

On Compute Engine, IDPF is available with a limited number of supported public OS images.

For information about which operating systems are supported with IDPF, see the Interfaces tab for an operating system.

Use on non-supported operating systems

For OS images that don't support IDPF, check with the operating system distributor about including the IDPF driver. You can manually configure and install the latest version of the IDPF driver as documented in https://github.com/intel/ethernet-linux-idpf/blob/main/README.

After you create a compute instance with an operating system image that supports IDPF, create a custom OS image. You can then use the custom OS image to create bare metal instances that use IDPF on that operating system.

Create a custom OS image that supports IDPF

If you require a different OS image or version for your bare metal instance than those provided by Google Cloud, you can create the OS image using either the Google Cloud CLI or REST. For detailed information and best practices for creating custom OS images, see Create custom OS images.

gcloud

When creating the custom image, either from a Google Cloud provided image or an imported OS image, you must tag the OS image with IDPF. Use the gcloud compute images create command as shown in the following example:

gcloud compute images create IMAGE_NAME \
    --source-image=SOURCE_IMAGE \
    --source-image-project=SOURCE_IMAGE_PROJECT \
    --guest-os-features=IDPF

Replace the following:

  • IMAGE_NAME: a name for the custom image.
  • SOURCE_IMAGE: a specific OS image that supports IDPF, for example: sles-sap-15-sp7-v20261014-x86-64.

    If you want to use the latest OS image in an image family, replace the --source-image flag with the --source-image-family flag and set its value to an image family that supports IDPF, for example: --source-image-family=sles-sap-15-sp7.

  • SOURCE_IMAGE_PROJECT: the name of the project that contains the source OS image or image family.

    Example

    To create a SUSE Linux Enterprise Server (SLES) OS image using the latest OS image from the Compute Engine sles-sap-15-sp7 image family, run the following command:

    gcloud compute images create my-sles15sp7-metal-os \
      --source-image-family=sles-sap-15-sp7 \
      --source-image-project=suse-sap-cloud \
      --guest-os-features=IDPF
    

    For more information about when to use image families, see Image family best practices.

REST

When creating the custom image, either from a Google Cloud provided image or an imported OS image, you must tag the OS image with IDPF. Complete the following steps:

  1. Select an OS image or image family that supports IDPF For more information, see Operating system details.

  2. Using the OS image or image family selected in the previous step, create an OS image and tag this OS image with IDPF. To create the OS image, use the images.insert method.

    POST https://compute.googleapis.com/compute/v1/projects/PROJECT_ID/global/images
    {
     "name":"IMAGE_NAME",
     "sourceImage":"SOURCE_IMAGE_URI",
     "guestOsFeatures":[
      {
         "type":"IDPF"
       }
     ]
    }
    

    Replace the following:

    • IMAGE_NAME: a name for the custom image that you are creating.
    • SOURCE_IMAGE_URI: the URI for the specific OS image or image family that you want to use.

      For example:

      • Specific OS image: "sourceImage": "projects/suse-sap-cloud/global/images/sles-sap-15-sp7-v20261014-x86-64"
      • Image family: "sourceImage": "projects/suse-sap-cloud/global/images/family/sles-sap-15-sp7".

      When you specify an image family, Compute Engine creates a VM from the most recent, non-deprecated OS image in that family. For more information about when to use image families, see Image family best practices.

Manually configure SR-IOV for C4D on Linux OS images

C4D bare metal machine types support multiple vNICs. These additional vNICs are exposed as virtual functions (VFs) on the network card. These VFs use the same IDPF network driver as other bare metal machine types.

To use these VFs in a custom Linux OS image, you must do the following:

  1. Query the number of VFs assigned to or supported by each network card.
  2. Activate the VFs either manually or by configuring udev rules.

Before configuring these VFs, note the following:

  • Network assignment uses a round-robin approach.
  • No traffic control is performed between VFs mapped to the same physical NIC. If traffic control is required for your workloads, then you must configure it yourself.

Prerequisites

To complete the steps documented in this section, you must have first completed the following tasks:

  • Created a bare metal instance that has SR-IOV enabled and multiple vNICs configured.
  • The IDPF kernel module is loaded in the Linux OS of the bare metal instance.
  • The guest OS must have the pciutils package installed to use the lspci command.

Activate the VFs

You can use one of the following methods to activate the VFs:

  • Configure udev rules.
  • Activate the VFs manually.

Configure udev rules for IDPF VFs

To configure SR-IOV using udev rules, complete the following steps:

  1. Add the following lines to the file /etc/udev/rules.d/75-gce-network.rules (or /lib/udev/rules.d/75-gce-network.rules):

    # Enable max number of VFs for Intel IDPF PF (8086:1452) FIRST
    SUBSYSTEM=="net", ACTION=="add", DRIVERS=="idpf", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1452", ATTR{device/sriov_numvfs}=="0", ATTR{device/sriov_numvfs}="$attr{device/sriov_totalvfs}"
    
  2. To immediately trigger the new udev rules, use the following commands:

    sudo udevadm control --reload-rules
    sudo udevadm trigger
    
  3. Verify the configuration by reading sriov_totalvfs to get the number of VFs supported by the primary NIC.

    The guest OS must have the pciutils package installed to use the lspci command.

    # Get the PCI address of the primary NIC
    lspci -D | grep -i eth
    
    # Use the PCI address (for example, 0000:3f:00.0) to read the number of VFs
    cat /sys/bus/pci/devices/0000:3f:00.0/sriov_totalvfs
    
    # Verify IP allocation for the VFs completed successfully
    ip a
    

Manually activate the SR-IOV VFs

You can manually activate all the supported SR-IOV VFs for your bare metal instance by completing the following steps:

  1. Identify the IDPF physical function (PF) by running the following command:

    lspci -D | grep -i eth
    

    The output from this command includes the PCI's bus:device.function address and the 4-digit domain prefix, for example 0000:3f:00.0 as shown in the following example output:

    0000:3f:00.0 Ethernet controller: Intel Corporation Infrastructure Data Path Function (rev 21)
    
  2. To enable all supported VFs, run the following command, replacing PCI_ADDRESS with the value from the previous step:

    cat /sys/bus/pci/devices/PCI_ADDRESS/sriov_totalvfs | sudo tee /sys/bus/pci/devices/PCI_ADDRESS/sriov_numvfs
    
  3. Verify that the new network PCI devices appear when you run the lspci command again. In addition, run the ip a command to verify that the IP allocation completed successfully for the VFs.

The network PCI devices are automatically configured by the OS's network management stack.

Create a bare metal instance with IDPF support

You can create a bare metal instance by using one of the public OS images that supports IDPF or by using a custom OS image that you created using the steps in Create a custom OS image that supports IDPF.

Create a bare metal instance using a public OS image

To create a bare metal instance using a public OS image that supports IDPF, follow the instructions at Create a bare metal instance.

Create a bare metal instance using a custom OS image

If you aren't using a public OS image that supports IDPF, you must first create a custom OS image that supports IDPF. You then use that custom OS image to create a bare metal instance by using the Google Cloud CLI or REST.

When creating the bare metal instance that supports more than one vNIC, you must specify all network interfaces during creation; you can't add an IDPF network interface to an existing instance. To add a vNIC to the command examples in the following tabs, do one of the following:

  • gcloud: add a --network-interface flag for each vNIC.
  • REST: add a networkInterfaces object for each vNIC.

gcloud

  1. Create the bare metal instance by using the gcloud compute instances create command. For the boot disk image, specify the custom OS image that you created earlier. For the network interface, set the value of the nic-type flag to IDPF.

    gcloud compute instances create INSTANCE_NAME \
        --zone=ZONE \
        --image=IMAGE_NAME \
        --image-project=YOUR_IMAGE_PROJECT \
        --network-interface=nic-type=IDPF
    

    Replace the following:

    • INSTANCE_NAME: a name for the new instance.
    • ZONE: the zone to create the instance in.
    • IMAGE_NAME: the custom OS image that was created previously.
    • YOUR_IMAGE_PROJECT: the name of the project that contains the custom OS image.
  2. Optional: Verify that Compute Engine created the instance and that the nicType is set to IDPF.

    gcloud compute instances describe INSTANCE_NAME \
       --zone=ZONE
    

    Replace the following:

    • INSTANCE_NAME: the name of the instance.
    • ZONE: the zone that you created the instance in.

    Example

    To create a bare metal instance in zone europe-west4-b using a customized SLES 15 SP7 for SAP OS image named my-sles15sp7-metal-os that's in project my-project-12345, run the following command:

    gcloud compute instances create test-x4-metal-custom-os \
        --zone=europe-west4-b \
        --machine-type=x4-1440-24t-metal \
        --image=my-sles15sp7-metal-os \
        --image-project=my-project-12345 \
        --network-interface=nic-type=IDPF
    

    Things to consider

    The --network-interface flag has sub-level flags such as the following:

    • --address: Assign an IP address to the instance
    • --network: The network the interface is to be a part of
    • --network-tier: The network tier of the interface
    • --subnet: The subnet that the interface is to be part of. If --network is also specified, the subnet must be a part of the specified network.
    • --private-network-ip: Specify the RFC 1918 IP to assign to the instance.

    For a full list see, the --network-interface flag.

    If the machine type for the instance supports more than one IDPF network interface, then you can configure the additional interfaces by specifying another --network-interface flag.

REST

Create the bare metal instance by using the instances.insert method.

  • For the boot disk image, specify the custom OS image that you created earlier.
  • For the network interface, set the value of the nicType field to IDPF.
POST https://compute.googleapis.com/compute/v1/projects/PROJECT_ID/zones/ZONE/instances
{
  "name":"INSTANCE_NAME",
  "networkInterfaces":[
    {
      "nicType":"IDPF",
      "network":"NETWORK",
      "subnetwork":"SUBNET_NAME"
    }
  ],
  "disks":[
    {
      "initializeParams":{
        "sourceImage":"projects/YOUR_IMAGE_PROJECT/global/images/IMAGE_NAME"
      },
      "boot":true
    }
  ]
}

If the machine type of the instance supports more than one IDPF network interface, then you can configure the additional interfaces by specifying another networkInterfaces object.

Replace the following:

  • PROJECT_ID: the ID of the project to create the instance in.
  • ZONE: the zone to create the instance in.
  • INSTANCE_NAME: a name for the new instance.
  • NETWORK: the URL of the network resource for this instance. If neither the network nor the subnetwork is specified, the default network global/networks/default is used.
  • SUBNET_NAME: name of the subnet. The network is inferred from the specified subnet. This is an optional field.
  • YOUR_IMAGE_PROJECT: the name of your project that contains the OS image.
  • IMAGE_NAME: the name of the custom OS image that was created in the previous step.

Verify that IDPF is enabled

You can use the lshw tool to extract detailed information about the hardware configuration of the bare metal instance.

To install the lshw tool on your Linux instance, open an SSH connection to the guest OS, and then run the following command:

sudo apt-get install lshw -y

To determine whether the instance is using the IDPF network interface, run the following command:

sudo lshw -class network

The following shows an example of the output:

*-network
       description: Ethernet interface
       product: Intel Corporation
       vendor: Intel Corporation
       physical id: 0
       bus info: pci@0000:3f:00.0
       logical name: enp5s0f0
       version: 11
       serial: 42:01:0a:96:00:02
       width: 64 bits
       clock: 33MHz
       capabilities: pm msi msix pciexpress bus_master cap_list ethernet physical
       configuration: autonegotiation=off broadcast=yes driver=idpf driverversion=6.5.0-1023-gcp duplex=full ip=10.150.0.2 latency=0 link=yes multicast=yes
       resources: iomemory:21ff0-21fef iomemory:21ff0-21fef irq:16 memory:21ffe0000000-21ffefffffff memory:21fff2000000-21fff203ffff

Manage SR-IOV VF-backed network interfaces on bare metal instances

If you create a bare metal instance using a machine type that supports multiple IDPF network interfaces with SR-IOV, then you can use the following tasks to manage the network interfaces that use SR-IOV virtual functions (VFs).

Find the PCI Address of the primary NIC

To view the PCI address of the IDPF LAN device, use the lspci command.

lspci -nn | grep -E 1452

The previous command displays the PCI address in the format bus:device.function, for example, 3f:00.0, as shown in the following example output:

3f:00.0 Ethernet controller [0200]: Intel Corporation Infrastructure Data Path Function [8086:1452] (rev 21)

Check if SR-IOV is supported by the LAN PF

To check if the SR-IOV PCIe capability is advertised by the LAN PF, use the lspci command. SR-IOV should be supported on all C4D bare metal instances. In the following command, replace PCI_ADDRESS with the PCI address of your LAN PF (the primary NIC).

 sudo lspci -vvv -s PCI_ADDRESS

The output is similar to the following:

3f:00.0 Ethernet controller: Intel Corporation Infrastructure Data Path Function (rev 21)
...
Capabilities: [210 v1] Single Root I/O Virtualization (SR-IOV)
        IOVCap: Migration- 10BitTagReq+ Interrupt Message Number: 000
        IOVCtl: Enable- Migration- Interrupt- MSE- ARIHierarchy+ 10BitTagReq-
        IOVSta: Migration-
        Initial VFs: 768, Total VFs: 768, Number of VFs: 0, Function Dependency Link: 00
        VF offset: 256, stride: 1, Device ID: 145c
        Supported Page Size: 00000553, System Page Size: 00000001
        Region 0: Memory at 0000018d94c00000 (64-bit, prefetchable)
        Region 2: Memory at 0000018e75d10000 (64-bit, prefetchable)
        VF Migration: offset: 00000000, BIR: 0
...

View the number of LAN VFs supported by the primary NIC

The sriov_totalvfs value in the PCIe SR-IOV capability exposes the maximum number of VFs that the hardware supports. The number of VFs that can be enabled depends on the number of IDPF network interfaces that you configured when you created the bare metal instance.

  1. Identify the IDPF physical function (PF) by running the following command:

    lspci -D | grep -i eth
    

    The output from this command includes the PCI's bus:device.function address and the 4-digit domain prefix, for example 0000:3f:00.0 as shown in the following example output:

    0000:3f:00.0 Ethernet controller: Intel Corporation Infrastructure Data Path Function (rev 21)
    
  2. To check the maximum number of SR-IOV VFs that can be enabled for your bare metal instance, run the following command, replacing PCI_ADDRESS with the domain and PCI address of your IDPF PF:

    cat /sys/bus/pci/devices/PCI_ADDRESS/sriov_totalvfs
    

If you created a C4D bare metal instance with three IDPF network interfaces, then you should see the following output:

2

The primary IDPF network interface uses the PF, and the remaining two network interfaces use VFs.

View the number of enabled LAN VFs

  1. Get the PCI address with the domain prefix for the LAN physical function (PF) by running the following command:

    lspci -D | grep -i eth
    
  2. To check how many VFs are enabled for your bare metal instance, run the following command, replacing PCI_ADDRESS with the PCI address (for example, 0000:3f:00.0) of your LAN PF:

    cat /sys/bus/pci/devices/PCI_ADDRESS/sriov_numvfs
    

If there are no enabled VFs, then the output of the command is 0.

VFs are not enabled until the guest operating system enables them. For information about how to enable the VFs, see Activate the VFs.

List the enabled LAN VFs

After enabling the virtual functions (VFs), the VF devices appear on the PCI bus with device ID 8086:145c. To list the enabled VF devices, run the following command:

   lspci -nnk -d 8086:145c
   

The following example shows the output for a bare metal instance with two enabled VFs. It also shows that the idpf driver initialized successfully on each VF:

02:00.0 Ethernet controller [0200]: Intel Corporation Infrastructure Data Path Function [8086:145c] (rev 21)
    Subsystem: Google, Inc. Device [1ae0:00c3]
    Kernel driver in use: idpf
02:00.1 Ethernet controller [0200]: Intel Corporation Infrastructure Data Path Function [8086:145c] (rev 21)
    Subsystem: Google, Inc. Device [1ae0:00c3]
    Kernel driver in use: idpf

Check if the IDPF driver initialized successfully on VFs

Check the dmesg log to ensure that the IDPF driver initialized without errors on the VFs:

sudo dmesg | grep idpf

The output should be similar to the following:

[    3.944639] idpf 0000:01:00.0: Device HW Reset initiated
[    4.089101] idpf 0000:01:00.0: Minimum RX descriptor support not provided, using the default
[    4.089631] idpf 0000:01:00.0: Minimum TX descriptor support not provided, using the default
[ 1408.197480] idpf 0000:02:00.0: enabling device (0000 -> 0002)
[ 1408.198223] idpf 0000:02:00.0: Device HW Reset initiated
[ 1408.199411] idpf 0000:02:00.1: enabling device (0000 -> 0002)
[ 1408.210608] idpf 0000:02:00.1: Device HW Reset initiated
[ 1408.480583] idpf 0000:02:00.1: PTP init failed, err=-EOPNOTSUPP
[ 1408.482380] idpf 0000:02:00.0: PTP init failed, err=-EOPNOTSUPP
[ 1408.495497] idpf 0000:02:00.0: Minimum RX descriptor support not provided, using the default
[ 1408.495500] idpf 0000:02:00.0: Minimum TX descriptor support not provided, using the default
[ 1408.495798] idpf 0000:02:00.1: Minimum RX descriptor support not provided, using the default
[ 1408.495802] idpf 0000:02:00.1: Minimum TX descriptor support not provided, using the default
[ 1408.907888] idpf 0000:02:00.0 enp1s0f0v0: renamed from eth1
[ 1408.948371] idpf 0000:02:00.1 enp1s0f0v1: renamed from eth2

View the IDPF network interfaces

If the IDPF driver initialized successfully, then the driver creates network interfaces which automatically obtain their IP address from the Virtual Private Cloud (VPC) network configuration.

 ip a

This following example output shows that the network interfaces are ready for use:

...
3: enp1s0f0v0:  mtu 1460 qdisc mq state UP group default qlen 1000
    link/ether 42:01:0a:00:02:03 brd ff:ff:ff:ff:ff:ff
    inet 10.0.2.3/32 metric 100 scope global dynamic enp1s0f0v0
       valid_lft 86144sec preferred_lft 86144sec
    inet6 fe80::4001:aff:fe00:203/64 scope link
       valid_lft forever preferred_lft forever
4: enp1s0f0v1:  mtu 1460 qdisc mq state UP group default qlen 1000
    link/ether 42:01:0a:00:03:03 brd ff:ff:ff:ff:ff:ff
    inet 10.0.3.3/32 metric 100 scope global dynamic enp1s0f0v1
       valid_lft 86144sec preferred_lft 86144sec
    inet6 fe80::4001:aff:fe00:303/64 scope link
       valid_lft forever preferred_lft forever

Disabling LAN VFs

To disable VFs, you write 0 to the sriov_numvfs sysfs file. This removes all the VF devices from the specified PCI bus. However, this doesn't remove the network interfaces configured for the bare metal instance.

To disable VFs for the bare metal instance, in the following command, replace PCI_ADDRESS with the PCI address of your LAN PF, for example 0000:3f:00.0:

 echo 0 | sudo tee /sys/bus/pci/devices/PCI_ADDRESS/sriov_numvfs

What's next